当前位置:首页  >  产品展示  >  德国HYDAC贺德克  >  HYDAC传感器  >  HDA4100系列HYDAC压力传感器特性介绍

HDA4100系列HYDAC压力传感器特性介绍
参考价:¥500

型号:

更新时间:2024-11-05  |  阅读:814

详情介绍

HDA4100系列HYDAC压力传感器特性介绍:

Available versions: Standard; ATEX; CSA; Schiff & Offshore;

The The pressure transducer series HDA 4100 is equipped with a ceramic pressure measurement cell with thick-layer DMS, which was specially developed for absolute pressure measurement in the low-pressure range. The 4 ... 20 mA or 0 ... 10V enable the connection to all measurement and control devices of HYDAC ELECTRONIC GmbH and the linkage to commercially available control and regulation units. The main areas of application lie in the low-pressure ranges of hydraulics and pneumatics, particularly in refrigeration and air-conditioning, food and pharmaceutical industry applications.

  • Accuracy ±0.5% FS type.
  • Measuring ranges: up to 2.5 bar absolute
  • Highly accurate temperatures
  • Excellent EMC characteristics
  • Very compact design
  • Convincing price/benefit ratio
  • Also available with ATEX, CSA or Schiffs approval

1. HYDAC压力传感器正确安装方法:
(1) 通过适当的仪表, 在普通大气压和标准温度条件下,核实压力传感器的频率反应值。
(2) 核实压力传感器的编码与相应的频率反应信号的正确性。
2. 确定具体安装位置
为了确定压力传感器的编号和具体安装位置, 需按充气网的各个充气段来考虑。
(1) 压力传感器必须沿着线缆进行安装, 安装在线缆接头处。
(2) 每条线缆装设压力传感器不少于4个, 靠近局的两个压力传感器, 相距不应大干200m。
(3) 每条线缆的始端和末端分别安装1个。
(4) 每条线缆的分支点应装1个, 如果两个分支点相距较近(小于100 m),可只装1个。
(5) 线缆敷设方式(架空、地下)改变处应装1个
(6) 对无分支的线缆, 因垒线的线缆程式*, 压力传感器的安装隔距不大干500m, 并使其总数不少于4个。
(7) 为了便于确定压力传感器故障点, 除在起点安装压力传感器外,距起点150~200m处,还要另外安装1个当然在设计中, 一定要考虑经济与技术的因素, 在不需要安装压力传感器的地方,则应不必安装。

HYDAC压力传感器现货型号展示:

HDA4445-A-400-000
HDA4744-A-100-000
HDA4744-A-160-000
HDA4744-A-250-000
HDA4744-B-250-000
HDA4744-B-600-000
HDA4745-A-006-000
HDA4745-A-010-000
HDA4745-A-016-000
HDA4745-A-040-000
HDA4745-A-060-000
HDA4745-A-100-000
HDA4745-A-160-000
HDA4745-A-400-000

此产品信息版权归上海维特锐所有,如想详细了解请点击:HYDAC压力传感器

 

  • * 姓名:

  • * 电话:

  • * 单位:

  • * 验证码:

  • * 留言内容:

电话 询价

产品目录